High quality electric endoscope nail compartment components

The electric endoscope nail compartment is composed of a closing rod, a red firing rod lock, a firing handle, a nail anvil release button, a battery pack, a battery pack release plate, a manually operated access hole cover plate, a knife reverse switch, a knob, a joint fin, a nail compartment, a nail compartment clamping surface, a nail compartment alignment plate, a nail compartment alignment groove, a sewing nail protection nail plate, a nail anvil pliers, and a nail compartment pliers. The stapler includes a closed push tube and GST technology for nail storage. The battery pack must be installed before use. This product is suitable for cross cutting, cutting, and/or establishing a fit. This device can be used in various open or minimally invasive thoracic surgeries, digestive and hepatobiliary pancreatic surgeries, and can be used in conjunction with suture threads or tissue support materials. This instrument can also be used for liver parenchyma (hepatic vascular system and biliary structure), pancreatic transverse resection and resection surgery.

    Contact us

    $8-$10/ Piece

    Product Introduction

    Introduction to the electric endoscope nail compartment
    1. The electric endoscope nail compartment is used for transverse cutting, resection, or establishing anastomosis.
    2. The electric endoscopic nail compartment can be applied to various open or minimally invasive thoracic surgeries, digestive tract and hepatobiliary pancreatic surgeries.
    3. The electric endoscope nail compartment can be used in conjunction with suture thread or tissue support materials. This product can also be used for liver parenchyma (hepatic vascular system and biliary structure), pancreatic transection and resection surgery.
    endoscope nail compartment components-2wboendoscope nail compartment components-3jeyendoscope nail compartment components-48l3
    Indications for electric endoscope nail compartment
    The electric endoscopic nail compartment is suitable for the closure of residual ends or incisions in endoscopic gastrointestinal reconstruction and organ resection surgery.

    Product Precautions

    Precautions for electric endoscope nail compartment 
    1. Ensure that the organization is flat and correctly placed between the jaws. If there are bundles of tissue along the nail compartment, especially at the fork of the instrument clamp, it can lead to incomplete suture thread.
    2. The end indicator lines on the nail seat and the positioning groove of the nail bin indicate the termination of the sewing nail line, and the cutting line indicator on the cutting machine marked "cut" on the positioning groove of the nail bin.
    3. Ensure that the organization does not exceed the proximal indicator line on the extrusion device. The tissue squeezed into the instrument from outside the indicator line may be cut horizontally without the use of staples.
    endoscope nail compartment components-5756endoscope nail compartment components-6vpy

    Product Usage

    Usage of electric endoscope nail compartment
    The electric endoscope nail compartment is used as a medical device in surgery, for fixing and suturing human tissues and organs. The following is the usage method of the electric endoscope nail compartment:
    1. Install the nail compartment on the endoscope to ensure tight connection.
    2. Connect the nail compartment to the surgical instrument to ensure a tight connection.
    3. Before the surgery begins, fill the nail compartment with nails. The nail compartment can be filled with nails through pressure or gas inflation.
    4. During the surgery, place the nail compartment between the tissues and organs that need to be sutured to ensure proper positioning.
    5. Use surgical instruments to thread the nail through the tissue and pull the nail out from the other side to complete the suture.
    6. Repeat the above steps until the entire surgery is completed.
    7. After surgery, remove the nail compartment from the surgical site and clean and disinfect it for future use.
    It should be noted that the use of the electric endoscope nail compartment requires professional personnel to operate to ensure safety and effectiveness. At the same time, carefully read the instructions before use and follow the advice and guidance of a doctor.

    Color and Usage Range

    Color and scope of use of stapler nail compartment
    The color and usage range of the stapler nail compartment are as follows:
    1. White nail: The height of the matching nail is 2.5mm, and the forming height is 1.0mm. Mainly used for the closure of pulmonary arteries and veins in thoracic surgery and the closure of the jejunum and ileum in gastrointestinal surgery.
    2. Blue nail: The height of the matching nail is 3.5mm, and the forming height is 1.5mm. Mainly used for lung tissue resection in thoracic surgery, gastric body transection in gastrointestinal surgery, duodenal dissection, and gastrointestinal lateral anastomosis.
    3. Gold nail: The height of the matching nail is 3.8mm, and the forming height is 1.8mm. Mainly used for the resection of thicker lung tissue in thoracic surgery and for the resection of thicker parts such as the gastric antrum and colon in gastrointestinal surgery.
    4. Green nail: The height of the matching nail is 4.1mm, and the forming height is 2.0mm. Mainly used for the closure of lobar and segmental bronchi in thoracic surgery and the closure of rectum in gastrointestinal surgery.